© 2014 MIMAKI ENGINEERING CO.,LTD.
6.3.5
P.2
6.3.5 Linear Encoder Scale
1
2
3
4
5
6
7
8
5. Remove the screw from the left end of the linear encoder scale,
and detach the
Scale holder L
and
Linear encoder scale
together with the springs.
6. Remove the
Linear encoder scale
(screw x1).
7. Peel off the left end (the side with short shape hole) of the
protection film on the new
Linear encoder scale
.
8. Mount the
Scale holder L
on the
Linear encoder scale
so that
the surface where the protection film is stuck faces to the Y bar
side.
9. Engage the
Scale holder L
with the
scale base L
through a
spring, and mount the
Linear encoder scale
while peeling off
the protection film.
10. Reverse the disassembly procedure for the subsequent
reassemblies.
Linear encoder scale
Spring
Scale holder L
Scale base L
Linear encoder scale
Spring
Scale holder L
Scale holder L200
While at work, be sure not to attach fingerprints or oil
to the linear encoder scale. Also, pay attention not to
break or scratch it. (If contaminated, clean the scale
with a neutral detergent.)