© 2014 MIMAKI ENGINEERING CO.,LTD.
6.5.3
P.1
1
2
3
4
5
6
7
8
6.5.3 NCU Assy. (Nozzle Missing Detector)
Work procedures
1. Turn the main power OFF.
2. Remove the Front cover M and L.
3. Move slowly the carriage onto the platen by hand.
4. Remove the NCU absorber tray. (take off a hook).
5. Disconnect the all connectors.
6. Remove screws (x2) on the NCU frame, and then remove the
NCU Assy.
7. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
NCU Assy.
NCU absorber tray
NCU Assy.
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > NCU Assy. (Nozzle Missing Detector)
Model
JV300-130/160
Issued 2014.05.30 Revised
F/W ver
1.00
Remark
1.0
Rev.