The DSP Toolchest
408
Attack
[0, 1k] ms
The characteristic attack time of the application of the gain reduction. Longer attack times
will cause MIOComp to be less responsive to short transients. Short attack times are required
to use MIOComp as a signal limiter, but very short attack times can lead to distortion in the
output signal. The attack time is applied in the detector stage of MIOComp.
Release
[0, 5k] ms
The characteristic release time of the application of the gain reduction. Longer release times
will cause MIOComp to be maintain the gain reduction for a longer period of time after tran-
sients. Longer release times are appropriate when using MIOComp as a leveling amp/AGC.
Alternatively, shorter release times are appropriate when using MIOComp to increase the ap-
parent level of impulsive material. Very short release times can lead to distortion in the output
signal. The release time is applied in the detector stage of MIOComp.
Knee
[-0.5, 1]
Adjusts the shape of the knee of the compressor as the detector goes above threshold. When
knee is set to 0, the transition from no gain reduction to the specified ratio is immediate at
the specified threshold. As this parameter is increased, the transition between the 1:1 ratio
and the specified ratio is made more and more progressive, thus "softening" the action of
the compressor.
Out Ceiling
[-60, 0] dB
Sets the maximum output level of the compressor. The output signal is hard-clipped, post
compressor, at this signal level.
Makeup Gain
[-30, 30] dB
Sets the additional gain applied to the signal post-compressor, regardless of whether or not
there is any gain reduction engaged. Without
Auto Gain
, it allows you to increase the the
output level. With
Auto Gain
, it allows you to trim the output level to taste.
Auto Gain
{Off, On}
When enabled, causes the compressor to automatically adjust the makeup gain to keep full-
scale input approximately at full-scale on output. This is a heuristic rule based on extensive
real-world testing across a wide variety of program material, intended for quick setup of basic
automatic level control. The makeup gain that is auto-generated is only strictly correct when
the attack is set to 0; so apply the manual
Makeup Gain
to trim the final output signal as
necessary.
Detector Source
{Input, SC-In}
Chooses the detector input source. Select between the input signal, and the sidechain input.
Master Bypass
{On, Off}
When enabled, fully bypasses the plugin.
See also:
MIOEq 6 Band
• Synopsis: 6 band Fully parametric EQ
Содержание 3d Upgrade Board Set
Страница 1: ...Metric Halo 3d Users Guide...
Страница 111: ...2882 Specifications 171...
Страница 183: ...Installation and Registration 183 Figure 9 7 Security Privacy Privacy tab Allow MIOConsole3d access to Microphone...
Страница 456: ...The DSP Toolchest 456 Parameters F 10 20k Sets the crossover frequency in Hz of the bandsplit...