Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Wall-Mount)
RS-232 Serial CIT Cable Installation
1 - 4 4
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Procedure
Step 1
Connect the RJ-45 end of the CIT cable to the
RS232
jack located on
the VLNC1 (SYSCTL).
...........................................................................................................................................................................
Step 2
Connect the 9-pin D-type connector to the serial port on the PC.
...........................................................................................................................................................................
Step 3
Check off the appropriate box in Appendix E, Installation Checklist.
End of Steps
...........................................................................................................................................................................
Table 1-15
RJ-45 to DB-9 Connector Connections
From RJ45
connector
To DB-9 Pin D-type
connector
Pin#
Color
Pin#
1
Blue
6
3
Black
4
4
Red
5
5
Green
2
6
Yellow
3
Notes:
1. The connection and the colors shown above are for RJ-45 to DB-
9 connector.
2. This connector should be used with a standard straight-through
10BASE-T LAN cable.
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...