Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Rack-Mount)
DS3 Cable Installation
...........................................................................................................................................................................................................................................................
2 - 2 3
365-372-334 R2.0
Issue 4, November 2004
Procedure
Step 1
Refer to the engineering job specification. Obtain the DS3 cables per
Table 2-7, DS3 Cable Assemblies and note the function group where
each cable will be used. Label the cables, indicating bay, shelf, function
group (B) and direction (IN or OUT of the bay) at each end.
...........................................................................................................................................................................
Step 2
Connect one end of the cable to the respective Receptacle on the access
panel on the rear of the Rack-Mount Metropolis
®
DMXplore shelf as
shown in Figure 2-9, DS3 Access Panel Cable Connectors (page 2-23).
Figure 2-9
DS3 Access Panel Cable Connectors
...........................................................................................................................................................................
Step 3
Route the cables along the cable rack and into the terminating bay.
...........................................................................................................................................................................
Step 4
Connect the cables to their respective positions on the terminating
equipment.
...........................................................................................................................................................................
Step 5
Check off the appropriate box in Appendix E, Installation Checklist.
End of Steps
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...