Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Wall-Mount)
Power Cable Installation
...........................................................................................................................................................................................................................................................
1 - 1 9
365-372-334 R2.0
Issue 4, November 2004
Important!
To tie RTN-A and RTN-B together use a MESH
Ground Strap to jumper between RTN-COM and GND of the
power terminal block.
...........................................................................................................................................................................
CAUTION
Verify that the AC/DC converter is not plugged into the AC
power outlet, or that BDCBB breakers are off, or that the BDFB
fuses are not installed.
...........................................................................................................................................................................
Procedure
Step 1
Verify the power source is off.
...........................................................................................................................................................................
Step 2
Connect the A and B power cables to the A and B connector pins of the
terminal block located on the top right of the access panel. Use a torque
screwdriver set to 0.5 Nm (4.4 lb-in) to tighten. See Figure 1-9, Power
Connection (page 1-20).
Important!
Power cables must be between 12 AWG and 20 AWG
and have an 8mm wire strip length for connection to the terminal
block.
BAT B
-48-B
BAT B
RTN-B
BAT B RTN
Table 1-3
Power Connections
Shelf Power
Designation
Name
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...