Operational Tests
Office Alarm Test
...........................................................................................................................................................................................................................................................
7 - 7
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Step 11
Follow Steps 1 to 5 to provision notification code for all DS1 and/or
DS3 ports to MJ
Example:
ent-rr:lt-dmxplore:a-all:ctag:::NTFCNCDE=MJ;
Important!
Select MJ instead of MN in Step 4.
...........................................................................................................................................................................
Step 12
Click
Send
to issue the command.
Result:
The
Response Window
will display the command
followed by a
COMPLD
indication.
...........................................................................................................................................................................
Step 13
Remove the valid DS1 or DS3 signal.
Result:
Activated office alarms:
CR/MJ
visual, CR/MJ audible.
...........................................................................................................................................................................
Step 14
Press the
ACO
push-button on the SYSCTL.
Result:
Activated office alarm:
CR/MJ
visual.
The CR/MJ audible alarm clears.
...........................................................................................................................................................................
Step 15
Reconnect valid DS1 or DS3 signal, and wait for alarms to clear.
...........................................................................................................................................................................
Step 16
Follow Steps 1 to 5 to provision notification code for all ports to NA
Example:
ent-rr:lt-dmxplore:a-all:ctag:::NTFCNCDE=NA;
Important!
Select NA instead of MN in Step 4.
...........................................................................................................................................................................
Step 17
Click
Send
to issue the command.
Result:
The
Response Window
will display the command
followed by a
COMPLD
indication.
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...