Software Download and Circuit Pack Installation
Circuit Pack Firmware Version Verification
5 - 1 8
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
Circuit Pack Firmware Version Verification
Description
This section provides instructions verifying that firmware versions on
the circuit packs in the Metropolis
®
DMXplore shelf. The procedures in
this section assume that the SYSCTL is installed and software has been
successfully downloaded and the circuit packs have been installed in
the shelf as described in the preceding sections.
...........................................................................................................................................................................
Circuit Pack Firmware
Version Verification
Procedure
Step 1
Log on to the Metropolis
®
DMXplore shelf using the CIT software as
described in the Use of WaveStar® CIT Software (page 5-8).
...........................................................................................................................................................................
Step 2
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-eqpt
command.
...........................................................................................................................................................................
Step 3
Click on the
rtrv-eqpt
command.
Result:
A command similar to the following example should be
displayed in the command window to the left of the
Send
button.
Example:
rtrv-eqpt:LT-DMXPLORE:all:1;
...........................................................................................................................................................................
Step 4
Click
Send
to issue the command.
Result:
The
Response Window
will display an output similar to
the following:
rtrv-eqpt:LT-DMXPLORE:all:1;
LT-DMXPLORE 93-10-26 16:42:11
M 1 COMPLD
"main-1::TYPE=OC-3/16DS1,APP=VLNC6,CLEI=,ECI=,SLN=,VRSN="1.0.1"
"main-2::TYPE=OC-3/16DS1,APP=VLNC6,CLEI=,ECI=,SLN=,VRSN="1.0.1"
"sysctl::TYPE=SYSCTL,APP=VLNC1,SSN=S1-1,CLEI=,ECI=,SLN=,VRSN=1.0.0”
"shelf::TYPE=DMXplore,APP=,CLEI=,ECI=,SLN="
;
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...