Operational Tests
Automatic Protection Switching and Alarm Test
...........................................................................................................................................................................................................................................................
7 - 1 1
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Step 7
Click
Send
to issue a second
rtrv-oc3
or rtrv-oc12 command.
Result:
The Response Window displays the command followed by
a
COMPLD
indication as well as indicating that the OLIU that was
active in the previous step is now "aps-line-fail" and the other OLIU
is now "active".
...........................................................................................................................................................................
Step 8
Reconnect the optical fiber to the OLIU.
Result:
After a short time, the
MN/ABN
alarm LEDs on the
SYSCTL and the
FAULT
LED on the OLIU will extinguish.
...........................................................................................................................................................................
Step 9
Repeat Step 4 through Step 8 to verify a switch back to the OLIU that
was originally active.
...........................................................................................................................................................................
Step 10
Check off the appropriate box in Appendix E, Installation Checklist.
End of Steps
...........................................................................................................................................................................
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...