...........................................................................................................................................................................................................................................................
Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Wall-Mount)
Miscellaneous (Environmental) Discrete
Telemetry Cable Installation
1 - 3 8
365-372-334 R2.0
Issue 4, November 2004
Important!
Typically, the MDO (out) of the lowest Metropolis
®
DMXplore in a bay is connected to the patch panel and MDI (in) is
connected to the next higher Metropolis
®
DMXplore MDO.
...........................................................................................................................................................................
Procedure
This procedure is performed for Metropolis
®
DMXplore shelves
requiring miscellaneous (environmental) discrete telemetry.
Step 1
Connect the miscellaneous discrete telemetry cables to the MDI and
MDO terminal blocks on the access panel of the Metropolis
®
DMXplore shelf per Figure 1-16, Miscellaneous Discrete Cable
Connection (page 1-39).
Table 1-12
Miscellaneous (Environmental) Discrete Telemetry
Connections
Pin#
Color
Designation
Name
1
2
3
4
BL
BL/W
O
O/W
Circuit #1 +
Circuit #1 -
Circuit #2 +
Circuit #2 -
Env. Input/Output - #1
Env. Input/Output - #2
Env. Input/Output - #3
Env. Input/Output - #4
5
6
7
8
G
G/W
BR
BR/W
Circuit #3 +
Circuit #3 -
Circuit #4 +
Circuit #4 -
Env. Input/Output - #5
Env. Input/Output - #6
Env. Input/Output - #7
Env. Input/Output - #8
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...