Software Download and Circuit Pack Installation
Circuit Pack Installation
5 - 6
365-372-334 R2.0
Issue 4, November 2004
Circuit Pack Installation
Procedure
Step 1
If applicable, fully insert the MAIN 1 OLIU circuit pack and then
MAIN 2 OLIU circuit pack into the shelf.
Important!
If installing two MAIN OLIUs, both circuit packs
must be the same type, either both VLNC5s, VLNC6s, VLNC25s
or VLNC26s.
Important!
Unlatch the circuit pack and using a gentle steady
pressure on both ends of the circuit pack, slide the circuit pack into
the slot until it is fully seated. Then close the faceplate latch.
...........................................................................................................................................................................
Step 2
If the Main 2 slot is to remain unequipped, fully seat the 199M
Apparatus Blank in the slot.
Important!
Unlatch the circuit pack and using a gentle steady
pressure on both ends of the circuit pack, slide the circuit pack into
the slot until it is fully seated. Then close the faceplate latch.
...........................................................................................................................................................................
Step 3
Connect
OUT
to
IN
on the MAIN-1 OLIU of the Metropolis
®
DMXplore shelf using an optical fiber jumper cable. Refer to Appendix
B, Fiber Cleaning for proper fiber cleaning instructions.
Connect
OUT
to
IN
on the MAIN-2 OLIU of the Metropolis
®
DMXplore shelf using an optical fiber jumper cable.
Result:
After a few minutes the flashing
FAULT
LEDs
extinguishes on each OLIU circuit pack. The
FAULT
and the
CR/MJ
LEDs light on the SYSCTL due to DCC alarms created by
optically looping the OLIUs. These SYSCTL LEDs remain lighted
until the DCC is disabled in the section labeled Clearing Alarms
(page 6-7).
...........................................................................................................................................................................
Step 4
Fully seat the VLNC15 10/100 Base T FE circuit pack if equipped or
the 199L Apparatus Blank in the function group C slot.
Important!
Unlatch the circuit pack and using a gentle steady
pressure on both ends of the circuit pack, slide the circuit pack into
the slot until it is fully seated. Then close the faceplate latch.
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...