Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Rack-Mount)
DS3 Cable Installation
2 - 2 2
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
DS3 Cable Installation
Description
This section describes how to connect the DS3 transmission cables to
the B function group of the shelf. If applicable, route the cables out of
the bay and connect the cables to the DSX panel.
Important!
When cabling the Metropolis
®
DMXplore to a DSX,
the DSX becomes an extension of the Metropolis
®
DMXplore
access panel connections. Thus the IN on the Metropolis
®
DMXplore access panel connects to the IN of the DSX and the
OUT of the Metropolis
®
DMXplore access panel connects to the
OUT of the DSX, respectively.
The cables are connectorized at the Metropolis
®
DMXplore end and
will need to be connected to the appropriate BNC termination at the
other end. The B function group supports a maximum of two DS3 drop
capacity.
DS3 cable options are listed in Table 2-7, DS3 Cable Assemblies (page
2-22).
...........................................................................................................................................................................
Table 2-7
DS3 Cable Assemblies
Description
Cable
Assembly #
Cable Length
(feet)
DS3 Cables, 735A coaxial,
Straight BNC (terminated)
plug to Straight BNC
(shipped loose) plug, 26
gauge
109468140
8
108785536
20
108785569
50
108785601
100
108785635
150
108785718
250
1. One code provides one DS3 input and one DS3 output cable.
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...