Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXplore Shelf (Rack-Mount)
Initial Circuit Pack Installation
...........................................................................................................................................................................................................................................................
4 - 1 1
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
Initial Circuit Pack Installation
Description
This section provides instructions for installing, BUT NOT fully
seating, circuit packs into the Metropolis
®
DMXplore shelf. After
circuit packs have been unpacked, they may be placed in their
respective slots in the Metropolis
®
DMXplore shelf but NOT FULLY
ENGAGED IN THE BACKPLANE CONNECTOR. The circuit packs
will be fully installed (seated) in the section, Circuit Pack Installation
(page 5-5).
Important!
If office alarms are connected, it is advisable to
disconnect the office alarm cable while performing the procedures
in this section to prevent spurious alarms from being reported.
Reconnect the office alarm cable after completion of all testing.
CAUTION
199M Apparatus Blanks are required in an unequipped Main-2
slot to provide proper air flow for cooling.
199L Apparatus Blanks are required in an unequipped C
Function Unit slot to provide proper air flow for cooling.
CAUTION
To protect against damage due to electrostatic discharge, a
properly grounded ESD wrist strap must be worn when handling
equipment.
VLNC1 (SYSCTL)
Installation
Follow this procedure to install the VLNC1 (SYSCTL) circuit pack
into the Metropolis
®
DMXplore shelf.
Step 1
Remove the SYSCTL circuit pack from the packing material.
...........................................................................................................................................................................
Step 2
Identify the lower right-hand slot on the Metropolis
®
DMXplore shelf.
See Figure 4-2, Rack-Mount Metropolis
®
DMXplore Shelf Front View
(page 4-7).
Содержание Metropolis DMXplore
Страница 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Страница 224: ... Metropolis DMXplore Access Multiplexer Ring Setup and Testing P A R T x x 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 258: ... Laser Safety and Classifications Metropolis DMXplore Optical Specifications A 8 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 270: ... Fiber Cleaning Cleaning Inspecting Optical Connectors B 1 2 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Страница 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...