background image

®

An ISO 9001:2015 Company

BENCH  TYPE  DIGITAL  MULTIMETER 

WITH PC INTERFACE

MODEL KM 8045

Содержание KM 8045

Страница 1: ... An ISO 9001 2015 Company BENCH TYPE DIGITAL MULTIMETER WITH PC INTERFACE MODEL KM 8045 ...

Страница 2: ...CONTENTS 1 GENERAL 1 2 SPECIFICATIONS 1 3 PANEL DESCRIPTION 7 4 OPERATION 8 5 MAINTENANCE 11 6 TEST CERTIFICATE 12 7 WARRANTY 13 ...

Страница 3: ...suring it is performed by high accuracy TRMS can test the bandwidth of the frequency the TMS of any waveform can be accurately measured 2 SPECIFICATION 220V 110V AC Power supply Manual Range 4 digit large LCD display with backlight displaying range max reading 75 x 40mm 19999 Voltage measurement upto 1000V DC and V AC 1000 DC AC current upto 20A ACV frequency response 50kHz Frequency resistance ca...

Страница 4: ...0 05 rdg 3dgts 0 1 rdg 5dgts 10 mV 100 mV 1 mV 10 mV 100 mV Input resistance 10MW for all ranges Overload protection 200mV range 250V DC or AC peak value Other range 1000VDC or AC peak value 2 Display 1 TRUE RMS 2 part range maybe can not return to zero it s normal has no effect on the tested accuracy This meter has the TRUE RMS function and extended the frequency response can accurately test the ...

Страница 5: ...ts 3 rdg 60 dgts 10 rdg 250 dgts 100 mV 1 mV 10 mV 100 mV 0 5 rdg 30 dgts 2 rdg 30 dgts 5 rdg 60 dgts 0 5 rdg 30 dgts 2 rdg 30 dgts 3 rdg 60 dgts 0 5 rdg 30 dgts 2 rdg 30 dgts 0 8 rdg 10 dgts 1 2 rdg 80 dgts 40Hz 1kHz 1kHz 10kHz 10kHz 20kHz 40Hz 1kHz 1kHz 10kHz 10kHz 20kHz 40Hz 1kHz 1kHz 5kHz 40Hz 200Hz 200Hz 400Hz Display 1 TRUE RMS applicable for range 10 or 100 2 Part range maybe can not return...

Страница 6: ...2A 250V fuse 20A 250V fuse Overload Protection LOAD VOLTAGE 1 mV uA 101 mV mA 11 mV mA 275 mV A 40Hz 400Hz AC CURRENT ACA TRUE RMS RANGE RANGE ACCURACY RESOLUTION 0 8 rdg 80 dgts 20 mA 2 A 200 mA 1 mA 100 mA 10 mA 1 0 rdg 50 dgts 20 A 1 mA Max Input current 20A within 15s 2A 250V fuse 20A 250V fuse Overload Protection LOAD VOLTAGE 11 mV A 1 5 mV A 275 mV A 42 mV A 1 5 mV mA 42 mV A ...

Страница 7: ...5uA OPEN CIRCUIT VOLTAGE Overload protection 250V DC or AC peak value Measuring error is not including lead resistance Resolution 1 pF 1 nF 10 pF 10 nF 100 pF 100 nF 1 mF Range 0nF 10nF 1mF 10mF 10nF 100nF 10mF 100mF 100nF 1mF 100mF 1mF 1mF 2mF CAPACITANCE CAP Accuracy 3 5 rdg 20dgts 5 rdg 30dgts Measuring Range of Accuracy 10 100 Large Capacitance response time 1mF about 8s Measured error is not ...

Страница 8: ...s Range hFE NPN or PNP hFE MEASURING 0 1000 0 Displaying Test Condition Basic current is approx 10mA Vce is approx 3V DIODE AND CONTINUITY TEST RANGE DISCRIPTION TEST CONDITION The measuring value is the approx Value for forward voltage drop when the resistance under tested is less than 0 20 buzzer sounds and display the approx Value 5 W W The open voltage is approx 3V Forward DCA is approx 1mA ba...

Страница 9: ...20V switch 15 Power switch 16 Power socket 17 Fuse 18 USB interface 3 PANEL DESCRIPTION 7 7 AC DC selection button 10 COM input terminal 11 V W Hz Cx input terminal 12 0 2 A input terminal 5 Hold button 6 Relative value button 8 Communication button 9 Rang Knob 4 3 2 1 5 6 7 8 9 13 12 11 10 14 15 16 17 18 ...

Страница 10: ...Black test lead to COM terminal and the red one to mA terminal max 2A or 20A terminal 2 Set the knob to DCA range connect the test leads across to the circuit under measured the polarity will be displayed with the voltage reading value 4 OPERATION 4 1 DCV The meter is driven by 220V 110V AC when operating connect the power to power plug firstly then socket Each meter is equipped with one pair of t...

Страница 11: ...e resistance is larger than the max Value of selected range displays Set the knob to a higher range OL When the resistance is 1M or larger than 1M it will take a few seconds to be stable it s normal in high resistance W W measuring 2 When the input terminal is n open circuit OL displays u der 3 When measuring resistance in line be sure that power of the circuit under measured is turned off and all...

Страница 12: ...nt it is preferable to use shielded cable for measuring small signal 3 Be careful when measuring high voltage circuit 4 8 CAPACITANCE MEASURING 1 Connect the test leads or shielded cable to VWHz and COM terminal 2 Set the knob to capacitance range connect the test leads across to the resistance under test 3 If zero is not displayed in the LCD Just press REL key 10 NOTE 1 If the current under measu...

Страница 13: ...uit must be replaced by qualified personal 2 NOTE 1 Be careful of waterproof dustproof and anti falling 2 Do not store or operate the meter in high temperature or strong magnetic place 3 Do not use the abrasives or solvents like alcohol to clean the meter 11 4 9 TRIODE hFE MEASURING 6 ACCESSORIES Test Leads USB cable Software CD Operating Manual Adapter Power cord NOTE 1 Do not input voltage or cu...

Страница 14: ...spected and tested in accordance with the published specifications The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards MODEL NO KM 8045 SERIAL NO ___________ DATE ___________ 12 BENCH TYPE DIGITAL MULTIMETER WITH PC INTERFACE ...

Страница 15: ...d contaminated or damaged by accident or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replacement of a defective product wh...

Страница 16: ...G 17 Bharat Industrial Estate T J Road Sewree W Mumbai 400015 INDIA Sales Direct 022 24156638 27754546 Tel 24124540 24181649 27750662 27750292 Email sales kusam meco co in Website www kusamelectrical com ...

Отзывы: