Lite-On Technology Corp.
Industrial Automation
128
Name
DI
Code
Input function
P
S
T
Sn
Tn
PS
PT
ST
DISABLE
0x00
No function
DI9
DI9
DI9
DI9
DI9
SVON
0x01
Servo on
DI1
DI1
DI1
DI1
DI1
DI1
DI1
DI1
ARST
0x02
Error reset
DI5
DI5
DI5
DI5
DI5
DI5
DI5
DI5
GAINUP
0x03
Gain switching
CCLR
0x04
Pulse cleaning
DI2
DI2
DI2
ZCLMP
0x05
Zero speed clamping
CMDV
0x06
Command input reverse
control
TRQL
0x07
Torque limit
DI2
DI2
DI2
SPDL
0x08
Speed limit
DI2
DI2
SPD0
0x09
Selection
of Speed Command
0
DI3
DI3
DI3
DI3
SPD1
0x0A
Selection
of Speed Command
1
DI4
DI4
DI4
DI4
TCM0
0x0B
Selection
of Torque
Command 0
DI3
DI3
DI3
DI3
DI6
TCM1
0x0C
Selection
of Torque
Command 1
DI4
DI4
DI4
DI4
DI7
S-P
0x0D
Switching of the speed/position
mixed mode
DI9
S-T
0x0E
Switching of the speed/torque
mixed mode
DI9
T-P
0x0F
Switching of the torque/position
mixed mode
DI9
EMG
0x15
Emergency stop
DI8
DI8
DI8
DI8
DI8
DI8
DI8
DI8
NL
0x16
Limit of reverse inhibition
DI6
DI6
DI6
DI6
DI6
DI6
DI6
PL
0x17
Limit of forward inhibition
DI7
DI7
DI7
DI7
DI7
DI7
DI7
JOGEN
0x19
Selection of the jog control
for the terminal
JOGU
0x1A
Forward jog input
JOGD
0x1B
Reverse jog input
GNUM0
0x21
Selection of the Numerator of
the Electronic Gear Ratio 0
GNUM1
0x22
Selection of the Numerator of
the Electronic Gear Ratio 1
TLLM
0x23
Reverse torque limit
TRLM
0x24
Forward torque limit
INHP
0x25
Pulse input inhibited
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved