Parameters for the planning of the digital I/O pin and for the setting related to the output
Parameter
Abbr.
Function
Initial
value
Unit
Control mode Remark
P
S
T
PA-20
INP
Confirmation of the range when the
position is reached
1000
pulse
O
PC-00
DIRT
The time for response filtering of the
digital input
2
2ms
O
O
O
PC-01
DI1
The function planning for Pin DI1 of the
digital input
101
N/A
O
O
O
PC-02
DI2
Function planning for Pin DI2 of the
digital input
104
N/A
O
O
O
PC-03
DI3
Function planning for Pin DI3 of the
digital input
116
N/A
O
O
O
PC-04
DI4
Function planning for Pin DI4 of the
digital input
117
N/A
O
O
O
PC-05
DI5
Function planning for Pin DI5 of the
digital input
102
N/A
O
O
O
PC-06
DI6
Function planning for Pin DI6 of the
digital input
22
N/A
O
O
O
PC-07
DI7
Function planning for Pin DI7 of the
digital input
23
N/A
O
O
O
PC-08
DI8
Function planning for Pin DI8 of the
digital input
21
N/A
O
O
O
PC-09
DI9
Function planning for Pin DI9 of the
digital input
0
N/A
O
O
O
PC-10
DO1
Function planning for Pin DO1 of the
digital output
101
N/A
O
O
O
PC-11
DO2
Function planning for Pin DO2 of the
digital output
103
N/A
O
O
O
PC-12
DO3
Function planning for Pin DO3 of the
digital output
109
N/A
O
O
O
PC-13
DO4
Function planning for Pin DO4 of the
digital output
105
N/A
O
O
O
PC-14
DO5
Function planning for Pin DO5 of the
digital output
7
N/A
O
O
O
PC-15
DO6
Function planning for Pin DO6 of the
digital output
7
N/A
O
O
O
PC-21
BTOD
The turn-on delay time for the
electromagnetic brake
0
ms
O
O
O
PC-22
BTCD
The turn-off delay time for the
electromagnetic brake
0
ms
O
O
O
PC-23
SPOK
The level for detection of the speed
comparison
10
r/min
O
PC-25
POL
The output level for the expected overload
0
%
O
O
O
PD-43
TSPD
The level for the detection of the target
rotation speed
The rated
value
r/min
O
O
O
(R-only)
This indicates the read-only register, which can only be used for reading status values.