Lite-On Technology Corp.
Industrial Automation
142
PD-19
(R-only)
MON5
The display for Condition Monitoring Register 5
Communication
address:
0326H
0327H
Initial value
-
Control mode
ALL
Unit
N/A
Configuration range
-
Data size
32bit
Data format
Dec
The status value to be read by PD-27 can be set via the panel or communication. (Refer to PD-21.) The status
data must be read from the communication address through the port.
PD-20
(N-keep)
ALD
The display for the error status of the drive
Communication
address:
0328H
0329H
Initial value
-
Control mode
ALL
Unit
N/A
Configuration range
0~58 (The alarm can be cleared
by writing in 0.)
Data size
16bit
Data format
Dec
Display of the hexadecimal value: The alarm code is displayed. (Refer to Chapter 9 Warning Troubleshooting
for the code definition.)
PD-21
SSD
Display for the status of the drive
Communication
address:
032AH
032BH
Initial value
0
Control mode
ALL
Unit
N/A
Configuration range
0 ~ 18
Data size
16bit
Data format
Dec