Lite-On Technology Corp.
Industrial Automation
40
reverse changes to inching rotation.
GNUM0
P, P-S
Select 0 for the electronic gear ratio.
(The numerator
of the gear ratio available (PA-11 ~ PA-13))
GNUM1
P, P-S
Select 1 for the electronic gear ratio.
(The numerator
of the gear ratio available (PA-11 ~ PA-13))
INHP
P, P-S
The pulse input is prohibited. In the position mode,
the external pulse input command is ineffective when
this signal is connected.