5.3.
No-load jog test
We propose the jog method to trial the motor and drive. The user does not need any extra distribution line,
which is really convenient. For safety reasons, it is suggested to jog the motor at low rotation speed. As for
the jog mode, the motor is set to move in constant velocity based on the set jog speed. The following is the
description we provided.
STEP
1
: Set Parameter PD-30. Enter the jog speed (unit: r/min) and press the SET key so that the drive
enters JOG mode.
STEP
2
: Press the Up key so that the motor turns clockwise. Press the "Down" key so that the motor turns
counterclockwise.
STEP
3
: Press the MODE key to exit JOG mode.
The following figure demonstrates the operation of the jog mode. Adjust the default initial value 20 rpm to
100rpm.
or
Press
: The servo motor rotates
counterclockwise.
Press
: The servo motor rotates
clockwise.
Press
to return:
Release the key and the motor stops instantly.
If there is no reaction, check the wiring for the
motor UVW and encoder.