Lite-On Technology Corp.
Industrial Automation
65
15
J-L
The load/motor inertia ratio
[double]
16
rSn.fr
The resonance frequency (The low byte is the first resonance
point and the high byte is the second resonance point.)
[Hz]
17
diFF.2
This indicates the number of absolute pulses with respect to
the encoder Z-phase. Which means, the numerical value at
the origin of the Z-phase is 0. The encoder rotates clockwise
or counterclockwise for positive/negative 5000 pulses.
[pulse]
18
Drv-t
Drive temperature
[°C]
4.4.
Operation of the general function
4.4.1.
Operation for displaying the record of the abnormal status
After entering the parameter modes PD-33 ~ PD-37, press the SET key to display the corresponding code of
the error history.
......
or
......
......
4.4.2.
Operation for the jog mode
After entering the parameter mode PD-30, execute the jog operating mode according to the following setting
methods.
(1) Press the SET key to display the jog speed. The initial value is 20 r/min.
(2) Press the UP or DOWN key to modify the jog speed to the desired value. For the example, the speed is
adjusted to 100r/min.
(3)Press the SET key to display JOG and enter the jog mode.
(4) After entering the jog mode, press the UP or DOWN key to make the servo motor to rotate clockwise or
counterclockwise. Release the button and the servo motor stops immediately. The jog operation is only
effective in the Servo On mode.
The first recent error
The second recent error
The third recent error
The fourth recent error
The fifth recent error