Lite-On Technology Corp.
Industrial Automation
115
PB-06
MFIL
The constant of the linear filtering for the analog
speed command
Communication
address:
010CH
010DH
Initial value
0
Control mode
S
Unit
0.1ms
Configuration range
0 ~ 40
Data size
16bit
Data format
Dec
Input example
10 = 1.0 ms
The filter is a moving filter. The parameter PB-00 is a low-pass filter. The difference is that the smoothing effect
occurs at the beginning and end of the step command for the moving filter. On the other hand, the smoothing
effect only occurs at the end of the step command for the low-pass filter.
Recommendation: If the speed loop receives the command from the upper computer to form the control of the
position loop, the low-pass filter can be used. For simple speed control, the moving filter can be used for better
smoothing effects.
PB-07
FRCL
Ratio of friction compensation
Communication
address:
010EH
010FH
Initial value
0
Control mode
P / S
Unit
%
Configuration range
0 ~ 100
Data size
16bit
Data format
Dec
This indicates the value for friction compensation. (As for the percentage of the rated torque, set 0 to turn off the
function for friction compensation and set 1 to turn it on.)
Time for step retaining
Analog speed command with
original stepping
Speed command after the linear
filter processing