PD-08
MNS
Monitoring mode
Communication
address:
0310H
0311H
Initial value
Control mode
Unit
Configuration range
Data size
Data format
PD-11
(R-only)
VER
The firmware version
Communication
address:
0316H
0317H
Initial value
The factory setting
Control mode
ALL
Unit
N/A
Configuration range
N/A
Data size
16bit
Data format
Dec
PD-15
(R-only)
MON1
The
display for Condition Monitoring Register 1
Communication
address:
031EH
031FH
Initial value
-
Control mode
ALL
Unit
N/A
Configuration range
-
Data size
32bit
Data format
Dec
The status value to be read by PD-23 can be set via the panel or communication. (Refer to PD-21.) The status
data must be read from the communication address through the port.
Example:
If PD-23 is set to 3, the "total pulse numbers for the motor with encoder feedback" is read when PD-15 is read.
If the content displayed is read via the MODBUS communication, two sets of 16-bit data from communication
addresses 0012H and 0013H is read, respectively. The contents of these two sets form the 32-bit data.