• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error code
Description
Action
server. See “Installing the blade server in a
BladeCenter unit” on page 39 and “Turning on
the blade server” on page 6.
3. Rerun the test. See “Diagnostic tools overview”
4. Make sure that the DSA Diagnostic code is up-
to-date, upgrade if necessary; then, rerun the
test. The latest code can be found on the IBM
support website at http://www-933.ibm.com/
support/fixcentral/systemx/groupView? query.
productGroup=ibm%2FBladeCenter.
5. Make sure that the IMM firmware level is up-to-
date, upgrade if necessary; then, rerun the test.
The installed firmware level can be found in the
DSA Diagnostic Event Log within the Firmware/
VPD section for this component. The latest level
firmware for this component can be found on
the IBM support website at http://www-933.ibm.
com/ support/fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
6. Turn off the blade server and reseat the blade
server in the blade server bay and turn on the
blade server. See “Removing the blade server
from the BladeCenter unit” on page 39 for more
information.
7. Rerun the test. See “Diagnostic tools overview”
8. If the failure remains, refer to Chapter 4
“Removing and replacing blade server
components” on page 37 to replace the failed
component.
166-906-xxx
Failed the IMM self test due to a failure in the
DIMM bus (BUS 5).
1. Turn off the blade server, open the blade server
release levers and pull the blade server away
from the blade module bay, but do not remove
it. See “Removing the blade server from the
BladeCenter unit” on page 39 for more
information.
2. Reseat the DIMMs (see “Removing a memory
module” on page 45 and “Installing a memory
module” on page 47).
3. Wait 45 seconds and reseat the blade server in
the blade module bay and turn on the blade
server. See “Installing the blade server in a
BladeCenter unit” on page 39 and “Turning on
the blade server” on page 6.
4. Rerun the test. See “Diagnostic tools overview”
5. Make sure that the DSA Diagnostic code is up-
to-date, upgrade if necessary; then, rerun the
231
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Страница 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 297: ......
Страница 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Страница 299: ... 1P00KC215 ...