• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Diagnostic
code
Message
Description
Action
S.68005
[S.68005] An error has
been detected by the IIO
core logic on Bus %.
The Global Fatal Error
Status register contains
%. The Global Non-
Fatal Error Status
register contains %.
Please check error logs
for the presence of
additional downstream
device error data.
Critical IOH-PCI Error.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Reseat the expansion cards (see “Removing
an I/O expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
3. Replace the following components one at a
time in the order shown, restarting the server
each time:
• Expansion cards (see “Removing an I/O
expansion card” on page 50 and
“Installing an I/O expansion card” on page
53).
• (Trained technician only) Replace the
system board (see “Removing the system-
board assembly” on page 71 and
“Installing the system-board assembly” on
page 71).
S.680B8
[S.680B8] Internal QPI
Link Failure Detected.
Internal QPI Link Failure
Detected.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Inspect the microprocessor socket for
foreign material, if the microprocessor socket
contains any foreign material, remove the
foreign material. If it is found damaged,
(trained technician only) replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
S.680B9
[S.680B9] External QPI
Link Failure Detected.
External QPI Link Failure
Detected.
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Inspect the microprocessor socket for
foreign material, if the microprocessor socket
contains any foreign material, remove the
foreign material. If it is found damaged,
(trained technician only) replace the system
board (see “Removing the system-board
assembly” on page 71 and “Installing the
system-board assembly” on page 71).
95
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...