• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
0x806f0607
806f0607-0301ffff
806f0607-0302ffff
Error
Processor
X
(CPU
X
) SM BIOS
uncorrectable
error [Note
X
=1,2]
1. Verify that you have
the latest system
firmware (see
“Updating firmware
and device drivers”
on page 23).
2. (Trained technician
only) If the error still
occurs, replace
microprocessor
X
(see “Removing a
microprocessor and
heat sink” on page 61
and “Installing a
microprocessor and
heat sink” on page
65).
3. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
“Removing the
system-board
assembly” on page
71 and “Installing the
system-board
assembly” on page
71).
0x806f0607
806f0607-2584ffff
Information
Group 4,
(processor 1-2)
processor (All
CPUs) SM BIOS
uncorrectable
error
1. Verify that you have
the latest system
firmware (see
“Updating firmware
and device drivers”
on page 23).
2. Clear the CMOS data
by removing the
system battery for 30
seconds (see
“Removing the
battery” on page 41
and “Installing the
battery” on page 42).
3. (Trained technician
only) If the error still
occurs, replace the
microprocessors one
at a time (see
177
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Страница 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 297: ......
Страница 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Страница 299: ... 1P00KC215 ...