Installing a microprocessor and heat sink
Use this information to install a microprocessor and heat sink in the blade server.
The following notes describe the type of microprocessor that the server supports and other information that
you must consider when you install a microprocessor:
• Each microprocessor socket must always contain either a socket cover and heat-sink filler or a
microprocessor and heat sink. If the blade server has only one microprocessor, it must be installed in
microprocessor socket 1.
• If you are installing a second microprocessor, make sure that the microprocessors are identical.
• Before you install a new microprocessor, download and install the most current level of UEFI code (see
“Updating firmware and device drivers” on page 23).
• When you install a second microprocessor, you might have to install additional memory, or redistribute
memory across the DIMM connectors (see “Installing a memory module” on page 47).
• The microprocessor installation tool might become worn after several uses. Make sure that the tool can
hold the microprocessor securely if you are reusing an existing microprocessor installation tool. Do not
return the tool with other parts that you are returning.
The following illustration shows how to install a microprocessor and heat sink in the blade server.
Microprocessor 2
and heat sink
Microprocessor 1
Heat sink
Microprocessor
heat sink filler
There are two types of microprocessor installation tools. The tools are similar in function and design,
however Tool A has one setting for installing one size of microprocessor, and supports the following families
of microprocessors: E5-26xx, E5-46xx. Installation Tool B has two settings for installing two different sizes of
microprocessors. The settings that are marked on Tool B are “L” for smaller low core microprocessors, and
“H” for larger high core microprocessors. Installation Tool B supports the following families of
microprocessors: E5-26xx, E5-46xx, E5-26xx v2, E5-46xx v2.
Microprocessor Installation Tools A and B are shown in the following illustration.
.
Removing and replacing blade server components
65
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Страница 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 297: ......
Страница 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Страница 299: ... 1P00KC215 ...