• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 “
Parts listing
” on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
Action
0x806f060d
806f060d-0401ffff
806f060d-0402ffff
Error
Hard drive
X
(Drive
X
) in failed array
[Note
X
=0,1]
1. Replace the storage
drive (see “Removing
a hot-swap storage
drive” on page 44 and
“Installing a hot-swap
storage drive” on
page 44).
2. After the storage drive
has been replaced,
rebuild the RAID array
(see “Configuring a
RAID array” on page
25).
0x806f070c
806f070c-2001ffff
806f070c-2002ffff
806f070c-2003ffff
806f070c-2004ffff
806f070c-2005ffff
806f070c-2006ffff
806f070c-2007ffff
806f070c-2008ffff
806f070c-2009ffff
806f070c-200affff
806f070c-200bffff
806f070c-200cffff
806f070c-200dffff
806f070c-200effff
806f070c-200fffff
806f070c-2010ffff
Error
Memory device
X
(DIMM
X
) memory
configuration error
[Note
X
=1-16]
Make sure that the
memory modules are
installed in the correct
order and configured
correctly (see “Installing a
memory module” on page
47).
0x806f070c
806f070c-2581ffff
Information
Group 1, (memory
device 1-16) (All
DIMMS) memory
configuration error
Make sure that the
memory modules are
installed in the correct
order and configured
correctly (see “Installing a
memory module” on page
47).
0x806f070c
806f070c-2581ffff
Information
Group 1, (memory
device 1-16) (One
of the DIMMS)
Memory
configuration error
Make sure that the
memory modules are
installed in the correct
order and configured
correctly (see “Installing a
memory module” on page
47).
179
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Страница 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 297: ......
Страница 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Страница 299: ... 1P00KC215 ...