
51
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
Indoor Unit A
1/4” liq + 1/2” gas
Indoor Unit B
1/4” liq + 1/2” gas
Indoor Unit C
1/4” liq + 3/8” gas
Indoor Unit D
1/4” liq + 3/8” gas
2
009 (B)
1
1/4 in. x 3/8 in.
018 (A)
1/4 in. x 1/2 in.
2
009 (B)
1
1/4 in. x 3/8 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
2
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
2
012 (B)
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
2
012 (B)
1/4 in. x 1/2 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
2
018 (B)
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
2
018 (B)
1/4 in. x 1/2 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
2
024 (B)
2, 3
3/8 in. x 5/8 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
3
009 (A)
1
1/4 in. x 3/8 in.
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
3
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
012 (A)
1/4 in. x 1/2 in.
3
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
018 (A)
1/4 in. x 1/2 in.
3
009 (C)
1/4 in. x 3/8 in.
009 (B)
1 1/4 in. x 1/2 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
3
009 (C)
1/4 in. x 3/8 in.
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
3
009 (C)
1/4 in. x 3/8 in.
012 (B)
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
3
009 (C)
1/4 in. x 3/8 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
012 (B)
1/4 in. x 1/2 in.
3
009 (C)
1/4 in. x 3/8 in.
018 (A)
1/4 in. x 1/2 in.
018 (B)
1/4 in. x 1/2 in.
3
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
012 (C)
1
1/4 in. x 1/2 in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished with outdoor unit).
2
1/4 x 3/8 in. liquid pipe adaptor is required for line set connection to the 048
outdoor unit (furnished with outdoor unit).
3
1/2 x 5/8 in. gas pipe adaptor is required for line set connection to the 048 outdoor
unit (furnished with outdoor unit).
4
Not a valid combination when using the MPA036S4M.
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
Indoor Unit A
1/4” liq + 1/2” gas
Indoor Unit B
1/4” liq + 1/2” gas
Indoor Unit C
1/4” liq + 3/8” gas
Indoor Unit D
1/4” liq + 3/8” gas
3
012 (B)
1/4 in. x 1/2 in.
012 (C)
1
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
3
012 (B)
1/4 in. x 1/2 in.
012 (C)
1
1/4 in. x 1/2 in.
024 (A)
2, 3
3/8 in. x 5/8 in.
3
012 (C)
1
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
018 (B)
1/4 in. x 1/2 in.
4
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
009 (D)
1/4 in. x 3/8 in.
009 (A)
1
1/4 in. x 3/8 in.
4
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
009 (D)
1/4 in. x 3/8 in.
012 (A)
1/4 in. x 1/2 in.
4
009 (B)
1
1/4 in. x 3/8 in.
009 (C)
1/4 in. x 3/8 in.
009 (D)
1/4 in. x 3/8 in.
018 (A)
1/4 in. x 1/2 in.
4
009 (C)
1/4 in. x 3/8 in.
009 (D)
1/4 in. x 3/8 in.
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
4
009 (C)
1/4 in. x 3/8 in.
009 (D)
1/4 in. x 3/8 in.
012 (B)
1/4 in. x 1/2 in.
018 (A)
1/4 in. x 1/2 in.
4
009 (D)
1/4 in. x 3/8 in.
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
012 (C)
1
1/4 in. x 1/2 in.
4
012 (A)
1/4 in. x 1/2 in.
012 (B)
1/4 in. x 1/2 in.
012 (C)
1
1/4 in. x 1/2 in.
012 (D)
1
1/4 in. x 1/2 in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished with outdoor unit).
2
1/4 x 3/8 in. liquid pipe adaptor is required for line set connection to the 048
outdoor unit (furnished with outdoor unit).
3
1/2 x 5/8 in. gas pipe adaptor is required for line set connection to the 048 outdoor
unit (furnished with outdoor unit).
4
Not a valid combination when using the MPA036S4M.
Содержание MWMA009S4-*L
Страница 105: ...105 Error Code E2 continued Check point button press 1 time to check how many indoor units are connected ...
Страница 110: ...110 Error Code E5 continued IPM for 4 zone P N for 2 zone and 3 zone IPM for 2 zone and 3 zone ...
Страница 111: ...111 Error Code E5 continued P N for 4 zone Bridge rectifier for 2 zone and 3 zone Bridge rectifier for 4 zone ...
Страница 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Страница 118: ...118 Error Code P1 continued ...
Страница 120: ...120 Error Code P2 continued ...
Страница 122: ...122 Error Code P3 continued ...
Страница 144: ...144 Error Code P0 continued P U P V ...
Страница 145: ...145 P W P N ...
Страница 151: ...151 Error Code P6 continued ...