MPB Multi-Zone Specifications Outdoor Units (1.5 - 2.5 Ton)
Nominal Size - Tons
1.5
2.5
Outdoor Unit Model No.
MPB018S4M
MPB030S4M
Number of Zones
2
Up to 3
1
AHRI Ratings
System Type
Ducted
Non-Ducted
Ducted
Non-Ducted
Cooling - Btuh
18,000
18,000
27,000
28,000
High Temperature Heating - Btuh
18,500
19,000
27,000
28,000
Low Temperature Heating - Btuh
11,400
12,000
16,200
17,200
SEER
18.4
22.5
18.5
23.0
EER
11.8
12.5
11.0
12.5
HSPF (Region IV)
9.4
10.3
9.0
10.3
AHRI Reference Number
10062011
10062010
10062013
10062012
Energy Star
No
Yes
No
Yes
Ambient Temperature Range - °F
Cooling
–13 - 122
–13 - 122
Heating
–13 - 86
–13 - 86
Sound Data (dBA)
Cooling
62
63
Heating
62
63
Refrigerant
Charge furnished (R-410A)
4 lbs. 7 oz.
6 lbs. 3 oz.
Maximum line length with furnished charge (per zone) - ft.
25
25
Additional charge required per ft. - oz.
0.161
0.161
Compressor
No. and Type
(1) Rotary
(1) Rotary
Refrigerant oil type
VG74
VG74
Refrigerant oil charge - oz.
16.9
22.7
Connections
Gas pipe (in.) flare
(2) 1/4 + (2) 3/8
(3) 1/4 + (3) 3/8
Max. length for all rooms - ft.
262
262
Max. length for one indoor unit - ft.
115
115
Max. height difference between indoor and outdoor units - ft.
49
49
Max. height difference between indoor units - ft.
33
33
Outdoor Fan
(No.) Diameter - in.
(1) 19
(1) 20
Total air volume - cfm
1390
2130
Motor rpm
150/200/250/300/350/450/550/650/
800/850
150/200/250/300/400/500/600/750/
900/1000
Outdoor Coil
Number of rows
2
2
Fins per inch
18
17
Fin type
Hydrophilic Aluminum
Tube outside diameter - in.
3/8
3/8
Tube type
Rifled Copper Tubing
Net face area - ft.
2
5.19
8.24
Application area - sq. ft.
260 - 375
430 - 630
Design Pressure
PSIG
550/340
550/340
Shipping Data
Net/Shipping weight (lbs.)
106 / 115
150 / 161
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase
208/230V
208/230V
2
Maximum Overcurrent Protection (amps)
25
35
3
Minimum circuit ampacity
18
25
Compressor Rated load amps
10
20
Outdoor Fan Motor
Rated load amps
0.74
0.9
Output - W
50
120
NOTE - Per AHRI, the certified ratings for systems are valid for
all
combinations of indoor units with the specific outdoor units listed above and in the AHRI Directory of
Certified Equipment. Please visit
for further details and latest updates.
1
Ratings are AHRI certified to AHRI Standard 1230-2010 with Addendum 2;
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Adaptors are furnished for the gas pipe connections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.
Содержание MWMA009S4-*L
Страница 105: ...105 Error Code E2 continued Check point button press 1 time to check how many indoor units are connected ...
Страница 110: ...110 Error Code E5 continued IPM for 4 zone P N for 2 zone and 3 zone IPM for 2 zone and 3 zone ...
Страница 111: ...111 Error Code E5 continued P N for 4 zone Bridge rectifier for 2 zone and 3 zone Bridge rectifier for 4 zone ...
Страница 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Страница 118: ...118 Error Code P1 continued ...
Страница 120: ...120 Error Code P2 continued ...
Страница 122: ...122 Error Code P3 continued ...
Страница 144: ...144 Error Code P0 continued P U P V ...
Страница 145: ...145 P W P N ...
Страница 151: ...151 Error Code P6 continued ...