39
NOTE - For multi-zone systems, the total capacity of all indoor units must be 66% to 133% of the outdoor unit capacity.
Outdoor Unit
Model No.
Number
of
Zones
Indoor Unit
Capacity
Nominal Cooling Capacity at Rated System
Capacity (Btuh)
Nominal Heating Capacity at Rated System
Capacity (Btuh)
#1
#2
#3
#4
#5
#1
#2
#3
#4
#5
#1
#2
#3
#4
#5
MPB048S4M
4
009 009 009 009 - - -
9,250
9,250
9,250
9,250
- - -
9,500
9,500
9,500
9,500
- - -
009 009 009 012 - - -
9,000
9,000
9,000
12,000
- - -
9,500
9,500
9,500
12,500
- - -
009 009 009 018 - - -
9,000
9,000
9,000
17,000
- - -
9,500
9,500
9,500
17,500
- - -
009 009 009
024
- - -
8,500
8,500
8,500
20,500
- - -
9,000
9,000
9,000
21,000
- - -
009 009 012 012 - - -
9,000
9,000
12,000 12,000
- - -
9,500
9,500
13,000 13,000
- - -
009 009 012 018 - - -
9,000
9,000
11,000 17,000
- - -
9,500
9,500
11,500 17,500
- - -
009 009 012
024
- - -
8,500
8,500
10,500 20,500
- - -
9,000
9,000
11,100 21,000
- - -
009 009 018 018 - - -
8,500
8,500
15,500 15,500
- - -
9,000
9,000
16,000 16,000
- - -
009 009 018
024
- - -
8,000
8,000
14,500
20,000
- - -
8,500
8,500
15,000 20,000
- - -
009 012 012 012 - - -
9,000
12,000 12,000 12,000
- - -
9,500
12,500 12,500 12,500
- - -
009 012 012 018 - - -
9,000
11,000 11,000 16,000
- - -
9,500
11,500 11,500 16,500
- - -
009 012 012
024
- - -
8,500
10,000 10,000 20,000
- - -
9,000
10,500 10,500 20,500
- - -
009 012 018 018 - - -
8,500
10,000 15,000 15,000
- - -
9,000
10,500 15,500 15,500
- - -
009 018 018 018 - - -
8,000
14,000 14,000 14,000
- - -
8,500
14,500 14,500 14,500
- - -
012 012 012 012 - - - 12,000 12,000 12,000 12,000
- - -
12,500 12,500 12,500 12,500
- - -
012 012 012 018 - - - 11,000 11,000 11,000 16,000
- - -
11,500 11,500 11,500 16,500
- - -
012 012 012
024
- - - 10,000 10,000 10,000 20,000
- - -
10,500 10,500 10,500 20,500
- - -
012 012 018 018 - - - 10,000 10,000 15,000 15,000
- - -
10,500 10,500 15,500 15,500
- - -
5
009 009 009 009 009 9,000
9,000
9,000
9,000
9,000
9,500
9,500
9,500
9,500
9,500
009 009 009 009 012 9,000
9,000
9,000
9,000
12,000
9,500
9,500
9,500
9,500
13,000
009 009 009 009 018 8,500
8,500
8,500
8,500
16,000
9,000
9,000
9,000
9,000
16,500
009 009 009 009
024
7,750
7,750
7,750
7,750
19,500
8,000
8,000
8,000
8,000
20,000
009 009 009 012 012 9,000
9,000
9,000
11,500 11,500
9,500
9,500
9,500
12,000 12,000
009 009 009 012 018 8,000
8,000
8,000
11,000 16,000
8,500
8,500
8,500
11,500 16,500
009 009 009 018 018 8,000
8,000
8,000
11,000 16,000
8,500
8,500
8,500
16,500 16,500
009 009 012 012 012 8,500
8,500
11,000 11,000 11,000
9,000
9,000
12,000 12,000 12,000
009 009 012 012 018 8,500
8,500
10,000 10,000 15,000
8,500
8,500
10,500 10,500 15,500
009 012 012 012 012 8,000
11,000 11,000 11,000 11,000
8,500
11,500 11,500 11,500 11,500
009 012 012 012 018 7,500
10,000 10,000 10,000
14,500
8,000
10,500 10,500 10,500 15,000
012 012 012 012 012 10,500 10,500 10,500 10,500 10,500 11,000 11,000 11,000 11,000 11,000
1
One outdoor unit may be matched with one indoor unit for single zone applications. A second indoor unit can be added at a later date for multi-zone applications.
Содержание MWMA009S4-*L
Страница 105: ...105 Error Code E2 continued Check point button press 1 time to check how many indoor units are connected ...
Страница 110: ...110 Error Code E5 continued IPM for 4 zone P N for 2 zone and 3 zone IPM for 2 zone and 3 zone ...
Страница 111: ...111 Error Code E5 continued P N for 4 zone Bridge rectifier for 2 zone and 3 zone Bridge rectifier for 4 zone ...
Страница 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Страница 118: ...118 Error Code P1 continued ...
Страница 120: ...120 Error Code P2 continued ...
Страница 122: ...122 Error Code P3 continued ...
Страница 144: ...144 Error Code P0 continued P U P V ...
Страница 145: ...145 P W P N ...
Страница 151: ...151 Error Code P6 continued ...