45
NOTE - Maximum Line Set
Length Includes ALL
piping in measurement
OUTDOOR UNIT
INDOOR UNIT
INDOOR UNIT
INDOOR UNIT
INDOOR UNIT
INDOOR UNIT
NOTE - Maximum Difference
in Elevation Between
Indoor Units - 33 ft. (10 m).
Maximum Line Set
Furthest Indoor Unit
Maximum
Elevation -
Outdoor Unit
BELOW
Indoor Units
Maximum
Elevation -
Outdoor Unit
ABOVE Indoor Unit
33 ft. (10 m) for MPA
49 ft. (15 m) for MLA and MPB
49 ft.
(15 m)
NOTE - Minimum Line Set
Length - 10 ft. (3 m) per
Indoor Unit
Outdoor Unit Model No.
MPA018S4M-*P
MPB018S4M-*P
MLA018S4M-*P
MPA030S4M-*P
MPB030S4M-*P
MLA030S4M-*P
MPA036S4M-*P
MPB036S4M-*P
MLA036S4M-*P
MPA048S4M-*P
MPB048S4M-*P
Maximum Number of Indoor
Units
Two
Three
Four
Five
Indoor Unit Connections -
Liquid / Gas
(2) 1/4 / 3/8
(3) 1/4 / 3/8
(3) 1/4 / 3/8
(1)1/4 / 1/2
(3) 1/4 / 3/8
(2) 1/4 / 1/2
Total Length of All Piping
98 ft. (30 m)
148 ft. (45 m)
197 ft. (60 m)
246 (75 m)
Maximum Line Set Length -
Furthest Indoor Unit
66 ft. (20 m)
82 ft. (25 m)
98 ft. (30 m)
98 ft. (30 m)
Figure 1. Multi-Zone Systems with All Indoor Unit Models
Содержание MWMA009S4-*L
Страница 105: ...105 Error Code E2 continued Check point button press 1 time to check how many indoor units are connected ...
Страница 110: ...110 Error Code E5 continued IPM for 4 zone P N for 2 zone and 3 zone IPM for 2 zone and 3 zone ...
Страница 111: ...111 Error Code E5 continued P N for 4 zone Bridge rectifier for 2 zone and 3 zone Bridge rectifier for 4 zone ...
Страница 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Страница 118: ...118 Error Code P1 continued ...
Страница 120: ...120 Error Code P2 continued ...
Страница 122: ...122 Error Code P3 continued ...
Страница 144: ...144 Error Code P0 continued P U P V ...
Страница 145: ...145 P W P N ...
Страница 151: ...151 Error Code P6 continued ...