35
6. Indoor / Outdoor Unit Combinations
6.1. MPA Multi-Zone System Combinations
NOTE - For multi-zone systems, the total capacity of all indoor units must be 66% to 133% of the outdoor unit capacity.
Outdoor Unit
Model No.
Number
of
Zones
Indoor Unit
Capacity
Nominal Cooling Capacity at Rated
System Capacity (Btuh)
Nominal Heating Capacity at Rated
System Capacity (Btuh)
#1 #2 #3 #4 #5
#1
#2
#3
#4
#5
#1
#2
#3
#4
#5
MPA018S4M
1
1
012 - - - - - - - - - - - - 11,977
- - -
- - -
- - -
- - -
11,373
- - -
- - -
- - -
- - -
2
009 009 - - - - - - - - - 9,000
9,000
- - -
- - -
- - -
9,250
9,250
- - -
- - -
- - -
009 012 - - - - - - - - - 8,379 10,313
- - -
- - -
- - -
8,538 10,508
- - -
- - -
- - -
012 012 - - - - - - - - -
9,450
9,450
- - -
- - -
- - -
9,735
9,735
- - -
- - -
- - -
MPA030S4M
1
1
018 - - - - - - - - - - - -
18,345
- - -
- - -
- - -
- - -
19,730
- - -
- - -
- - -
- - -
2
009 009 - - - - - - - - - 9,258
9,258
- - -
- - -
- - -
10,961 10,961
- - -
- - -
- - -
009 012 - - - - - - - - -
9,115 11,219
- - -
- - -
- - -
10,564
13,002
- - -
- - -
- - -
009 018 - - - - - - - - - 8,803
17,944
- - -
- - -
- - -
10,521
21,448
- - -
- - -
- - -
012 012 - - - - - - - - - 11,521 11,521
- - -
- - -
- - -
12,605 12,605
- - -
- - -
- - -
012 018 - - - - - - - - - 10,327 17,105
- - -
- - -
- - -
12,379 20,503
- - -
- - -
- - -
018 018 - - - - - - - - - 15,390 15,390
- - -
- - -
- - -
18,453 18,453
- - -
- - -
- - -
3
009 009 009 - - - - - - 8,915
8,915
8,915
- - -
- - -
10,656 10,656 10,656
- - -
- - -
009 009 012 - - - - - -
9,244
9,244
11,512
- - -
- - -
10,234 10,234
12,596
- - -
- - -
009 012 012 - - - - - - 8,681
10,684 10,684
- - -
- - -
9,605 11,821 11,821
- - -
- - -
009 009 018 - - - - - - 7,316
7,316
14,632
- - -
- - -
8,197
8,197
16,394
- - -
- - -
012 012 012 - - - - - - 9,755
9,755
9,755
- - -
- - -
10,929 10,929 10,929
- - -
- - -
MPA036S4M
2
009 018 - - - - - - - - - 8,788 17,913
- - -
- - -
- - -
9,540 19,447
- - -
- - -
- - -
012 012 - - - - - - - - - 10,287 10,287
- - -
- - -
- - -
11,864 11,864
- - -
- - -
- - -
012 018 - - - - - - - - - 10,052
16,649
- - -
- - -
- - -
10,913
18,074
- - -
- - -
- - -
018 018 - - - - - - - - - 17,200 17,200
- - -
- - -
- - -
18,240 18,240
- - -
- - -
- - -
3
009 009 009 - - - - - - 8,900
8,900
8,900
- - -
- - -
9,476
9,476
9,476
- - -
- - -
009 009 012 - - - - - - 8,265
8,265 10,172
- - -
- - -
8,972
8,972
11,043
- - -
- - -
009 009 018 - - - - - - 8,518
8,518
17,364
- - -
- - -
9,033
9,033
18,414
- - -
- - -
009 012 012 - - - - - - 9,228 11,357 11,357
- - -
- - -
10,301 12,679 12,679
- - -
- - -
009 012 018 - - - - - - 8,202
10,094
16,719
- - -
- - -
8,347
10,273 17,015
- - -
- - -
009 018 018 - - - - - -
7,640
15,575 15,575
- - -
- - -
7,664 15,624 15,624
- - -
- - -
012 012 012 - - - - - -
10,648 10,648 10,648
- - -
- - -
11,886 11,886 11,886
- - -
- - -
012 012 018 - - - - - - 9,901
9,901 16,399
- - -
- - -
10,031 10,031
16,614
- - -
- - -
012 018 018 - - - - - - 8,995
14,898 14,898
- - -
- - -
9,175 15,197 15,197
- - -
- - -
4
009 009 009 009 - - - 9,000
9,000
9,000
9,000
- - -
9,000
9,000
9,000
9,000
- - -
009 009 009 012 - - - 9,371
9,371
9,371
11,534
- - -
9,031
9,031
9,031 11,115
- - -
009 009 009 018 - - -
8,204
8,204
8,204
16,723
- - -
7,902
7,902
7,902 16,109
- - -
009 009 012 012 - - - 8,887
8,887 10,937 10,937
- - -
8,564
8,564 10,540 10,540
- - -
009 009 012 018 - - - 8,062
8,062
9,923
16,435
- - -
7,823
7,823
9,628
15,946
- - -
009 012 012 012 - - - 8,809
10,842 10,842 10,842
- - -
8,485 10,444 10,444 10,444
- - -
012 012 012 012 - - -
10,334 10,334 10,334 10,334
- - -
9,954
9,954
9,954
9,954
- - -
1
One outdoor unit may be matched with one indoor unit for single-zone applications. A second indoor unit can be added at a later date for multi-zone applications.
Содержание MWMA009S4-*L
Страница 105: ...105 Error Code E2 continued Check point button press 1 time to check how many indoor units are connected ...
Страница 110: ...110 Error Code E5 continued IPM for 4 zone P N for 2 zone and 3 zone IPM for 2 zone and 3 zone ...
Страница 111: ...111 Error Code E5 continued P N for 4 zone Bridge rectifier for 2 zone and 3 zone Bridge rectifier for 4 zone ...
Страница 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Страница 118: ...118 Error Code P1 continued ...
Страница 120: ...120 Error Code P2 continued ...
Страница 122: ...122 Error Code P3 continued ...
Страница 144: ...144 Error Code P0 continued P U P V ...
Страница 145: ...145 P W P N ...
Страница 151: ...151 Error Code P6 continued ...