twisting, where they are connected within the equipment, and shall protect
the insulation of the conductors from abrasion. The protective earth conductor
shall be last to take the strain if the cord slips in its anchorage.
Cord anchorages shall meet the following requirements:
The cord shall not be clamped by a screw that bears directly on the cord
Knots in the cord shall not be used
It shall not be possible to push the cord into the equipment to an extent
that could cause a hazard
Failure of the cord insulation in a cord anchorage that has metal parts
shall not cause accessible conductive parts to become hazardous live
It shall not be possible to loosen the cord anchorage without the use of
a tool
It shall be designed so that cord replacement does not cause a hazard,
and it shall be clear how the relief from strain is provided.
Warning
A compression bushing shall not be used as cord
anchorage.
Failure to meet the above requirements could make the
equipment unsafe resulting in a hazard and invalidate
the ATEX/IECEx certification.