160
Operating Manual
OMBG3000 – Iss.01
© Copyright 2016
8.3
Replacement BIOGAS 3000 Module for Service – Hot Swap
The BIOGAS 3000 has been designed to avoid unnecessary downtime and a
temporary BIOGAS 3000 module can be supplied during service upon request.
Below are instructions on how to swap out the BIOGAS 3000 module for
service.
Warning
Do not open when an explosive atmosphere is present.
Mains voltages are present within the BIOGAS 3000
system and great care needs to be observed. If there is
any uncertainty, seek advice from a professional or
isolate the supply. Alternatively, contact our technical
support team at (800) 968-2026 or email
to arrange a site visit.
(Please note a charge may be applicable.)
Op. Image
Instruction
1
Power off the module by holding
the on/off key for two seconds.
Note: This will freeze the
outputs at their last known
value
2
Disconnect the gas inlet and gas
outlet tubing from the top of the
BIOGAS 3000 module.
3
Disconnect the USB lead from the
communications connector and
the power supply lead from the
power supply connector from the
top of the BIOGAS 3000 module.