For non-critical faults at this stage, the user can continue by pressing the right
soft key ‘Continue’. The BIOGAS 3000 will continue automatically after thirty
seconds if continue is not pressed.
Screen 42 - Self-test with warnings
, there will be a non-critical
fault icon present on the ‘Gas Readings Screen’ during monitoring:
A non-critical fault does not stop the sampling process and this will continue as
normal. Examples of non-critical faults are a channel under-ranging or the
service being due.
Pressing the right soft key on the ‘Gas Readings Screen’ will display the non-
critical faults the system has detected.
Screen 43 - System Warnings (non-critical faults)
From this screen:
Pressing the left soft key will ‘Reset’ the system and power cycle the
BIOGAS 3000 module
Pressing the middle soft key will perform a system test. If the fault
clears after this, monitoring will resume and the icon will be removed