Operating Manual
161
© Copyright 2016
OMBG3000 – Rev1
4
Remove the four screws securing
the module mounting brackets to
the pillars using a 4mm Allen key.
Note: Keep the screws safe,
as they will be required to
secure the hot swap
module.
5
No image
Send the module to your
distributor or our service team at
LANDTEC.
6
Align the new module with the
four pillars and secure in place
using the four screws and 4mm
Allen key. The screws must be
tightened to 4N
m.
Warning
It is critical that the screws are torques to 4N
m. Failure
to tighten to this setting will invalidate the ATEX and
IECEx certification.
7
Reconnect the USB lead to the
communications connector and
the power supply lead to the
power supply connector at the
top of the BIOGAS 3000 module.
8
Reconnect the gas in and gas out
tubing to the module.
Note: Ensure that the
couplings are fully pushed
into the housing.
Note: The yellow tubing
should connect to the yellow