Preparation before Use
2-22
7
Enter "SMTP" and "E-mail Send Settings" items.
8
Click
Submit
.
Setting
Description
SMTP
Set to send e-mail from the machine.
SMTP Protocol
Displays the SMTP protocol settings. Check that
SMTP Protocol
is set to
On
. If
Off
is set, click
Protocol
and set the SMTP protocol to
On
.
SMTP Server Name
†
Enter the host name or IP address of the SMTP server.
SMTP Port Number
Specify the port number to be used for SMTP. Use the SMTP default port 25.
SMTP Server Timeout
Set the amount of time to wait before time-out in seconds.
Authentication Protocol
To use SMTP authentication, enter the user information for authentication.
SMTP Security
Set SMTP security.
Turn on
SMTP Security
in
SMTP (E-mail TX)
on the
Protocol Settings
page.
POP before SMTP
Timeout
Specify the time in seconds until the connection to the POP server times outs.
This can be set when
POP before SMTP
is selected in
Authentication
Protocol
.
Connection Test
Tests to confirm that the settings are correct.
Domain Restriction
To restrict the domains, click the
Domain List
and enter the domain names of
addresses to be allowed or rejected. Restriction can also be specified by e-mail
address.
POP3
POP3 Protocol
You don't need to set the following items when you only enable the function of
sending e-mail from the machine. Set the following items if you want to enable
the function of receiving e-mail on the machine. For more information, refer to
Command Center RX User Guide
.
Check Interval
Run once now
Domain Restriction
POP3 User Settings
E-mail
Send
Settings
E-mail Size Limit
Enter the maximum size of E-mail that can be sent in kilobytes. When E-mail
size is greater than this value, an error message appears and E-mail sending is
cancelled. Use this setting if you have set E-mail Size Limit for SMTP server. If
not, enter a value of 0 (zero) to enable E-mail sending regardless of the size
limit.
Sender Address
†
Specify the sender address for when the machine sends E-mails, such as the
machine administrator, so that a reply or non-delivery report will go to a person
rather than to the machine. The sender address must be entered correctly for
SMTP authentication. The maximum length of the sender address is 128
characters.
Signature
Enter the signature. The signature is free form text that will appear at the end of
the E-mail body. It is often used for further identification of the machine. The
maximum length of the signature is 512 characters.
Function Defaults
Change the function default settings in
Common/Job Default Settings
page.
†
Be sure to enter the items.
Содержание ECOSYS P4040dn
Страница 1: ...ECOSYS P4040dn PRINT OPERATION GUIDE ...
Страница 16: ...xii ...
Страница 22: ...Machine Parts 1 6 ...
Страница 58: ...Preparation before Use 2 36 ...
Страница 66: ...Printing 3 8 ...
Страница 202: ...Operation Panel 4 136 ...
Страница 250: ...Maintenance 7 12 ...
Страница 273: ...8 23 Troubleshooting 3 Close the rear cover 4 Open and close the top cover to clear the error ...
Страница 274: ...Troubleshooting 8 24 ...
Страница 306: ...Appendix A 32 ...
Страница 314: ...Index 4 W Waste Toner Box 1 2 Replacing 7 7 Wide A4 4 55 Wireless Network Interface Kit A 11 X XPS Fit to Page 4 55 ...
Страница 315: ......
Страница 318: ...Rev 1 2014 12 2P7KDEN001 ...