Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 514/1568
6.17.8
traceroute
6.17.8.1
traceroute
Use the traceroute command to discover the routes that packets actually take when traveling to their
destination through the network on a hop-by-hop basis. Traceroute continues to provide a synchronous
response when initiated from the CLI.
Syntax
traceroute <ipaddr|hostname> [initTtl <initTtl>] [maxTtl <maxTtl>]
[interval <interval>] [count <count>]
<ipaddr|hostname> -
The IP address or destination host you want to trace.
<initTtl> -
The Use initTtl to specify the initial time-to-live (TTL), the maximum number of router hops
between the local and remote system. Range is 1 to 255.
<maxTtl> -
Use maxTtle to specify the maximum TTL. Range is 1 to 255.
<interval> -
Use interval to specify the time between probes, in seconds. Range is 1 to 60 seconds.
<count> -
Use the optional count parameter to specify the number of probes to send for each TTL
value. Range is 1 to 10 probes.
Default Setting
None
Command Mode
Previledge Mode