6.6.2
Configuration Commands
6.6.2.1
Logging email
This command enables email alerting and sets the lowest serverity level for which log messages are
emailed. If you specify a severity level, log messages at or above this severity level, but below the urgent
severity level, are emailed in a non-urgent manner by collecting them together until the log time expires.
You can specify the
severitylevel
value as either an integer from 0 to 7 or symbolically through one of the
following keywords: emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6), or debug(7).
Syntax
logging email [{urgent | non-urgent} {<severity> | none}]
no logging email [{urgent | non-urgent}]
urgent -
Specify the severity level for the urgent messsages. The logging messages
’ severity is
lower than urgent severity level will be treated as urgent message and the logging message will be
sent immediately in a single email message if the email logging is enabled.
non-urgent -
Specify the severity level for the non-urgent messsages. The log messages at or
above this severity level, but below the urgent servrity level, are emailed in a non-urgent manner.
none -
Do not send logging messages if urgent or non-urgent severity level is set to none.
no parameter -
Indicates that to enable the logging email feature.
no -
This command restore the setting to default value.
Default Setting
Email logging is disabled
Urgent severity level is alert
Non-urgent severity level is warning
Command Mode
Global Config