Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 114/1568
6.2.5.9
garp timer
This command sets the GVRP join time per port and per GARP. Join time is the interval between the
transmission of GARP Protocol Data Units (PDUs) registering (or re-registering) membership for a VLAN
or multicast group.
This command has an effect only when GVRP and GMRP are enabled. The time is from 10 to 100
(centiseconds).
Syntax
garp timer join <10-100>
no garp timer join
<10-100> -
join time (Range: 10
– 100) in centiseconds.
no -
This command sets the GVRP join time per port and per GARP to 20 centiseconds (0.2
seconds). This command has an effect only when GVRP and GMRP are enabled.
Default Setting
20 centiseconds (0.2 seconds)
Command Mode
Interface Config
This command sets the GVRP join time for all ports and per GARP. Join time is the interval between the
transmission of GARP Protocol Data Units (PDUs) registering (or re-registering) membership for a VLAN
or multicast group.
This command has an effect only when GVRP and GMRP are enabled. The time is from 10 to 100
(centiseconds).
Syntax
garp timer join all < 10-100 >
no garp timer join all
<10-100> -
join time (Range: 10
– 100) in centiseconds.
all -
All interfaces.
no -
This command sets the GVRP join time for all ports and per GARP to 20 centiseconds (0.2
seconds). This command has an effect only when GVRP and GMRP are enabled.
Default Setting
20 centiseconds (0.2 seconds)