6.2.5.3
show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information for one or All
interfaces.
Syntax
show gmrp configuration [<slot/port>]
<slot/port> -
An interface number.
no parameter -
All interfaces.
Default Setting
None
Command Mode
Privileged Exec
User Exec
Display Message
Interface:
This displays the slot/port of the interface that this row in the table describes.
Join Timer:
Specifies the interval between the transmission of GARP PDUs registering (or
re-registering) membership for an attribute. Current attributes are a VLAN or multicast group. There
is an instance of this timer on a per-Port, per-GARP participant basis. Permissible values are 10 to
100 centiseconds (0.1 to 1.0 seconds). The factory default is 20 centiseconds (0.2 seconds). The
finest granularity of specification is 1 centisecond (0.01 seconds).
Leave Timer:
Specifies the period of time to wait after receiving an unregister request for an attribute
before deleting the attribute. Current attributes are a VLAN or multicast group. This may be
considered a buffer time for another station to assert registration for the same attribute in order to
maintain uninterrupted service. There is an instance of this timer on a per-Port, per-GARP participant
basis. Permissible values are 20 to 600 centiseconds (0.2 to 6.0 seconds). The factory default is 60
centiseconds (0.6 seconds). The finest granularity of specification is 1 centisecond (0.01 seconds).
LeaveAll Timer:
This Leave All Time controls how frequently LeaveAll PDUs are generated. A
LeaveAll PDU indicates that all registrations will shortly be deregistered. Participants will need to
rejoin in order to maintain registration. There is an instance of this timer on a per-Port, per-GARP
participant basis. The Leave All Period Timer is set to a random value in the range of LeaveAll- Time
to 1.5*LeaveAllTime. Permissible values are 200 to 6000 centiseconds (2 to 60 seconds). The factory
default is 1000 centiseconds (10 seconds). The finest granularity of specification is 1 centisecond
(0.01 seconds).
Port GMRP Mode:
Indicates the GMRP administrative mode for the port. It may be enabled or
disabled. If this parameter is disabled, Join Time, Leave Time, and Leave All Time have no effect.
The factory default is disabled.