This command is used to configure the email source address (the address of the sender, i.e., switch) to
which messages are sent.
Syntax
logging email from-addr <from-address>
no logging email from-addr
<from-address> -
Specify a standard email address for the source address of the email, for
example admin@yourcompany.com.
no -
This command removes the configured email source address.
Default Setting
None
Command Mode
Global Config
This command is used to configure the subject line of the email for the specified type.
Syntax
logging email message-type {both | urgent | non-urgent} subject <subject>
no logging email message-type {both | urgent | non-urgent} subject <subject>
<subject> -
Specify the subject line of the email. The length of the subject is 1 to 255 characters.
no -
This command removes the configured email subject for the specified message type and
restores it to the default email subject.
Default Setting
For urgent, the default subject is
“Urgent Log Messages”
For non-urgent, the default subject is
“Non Urgent Log Messages”
Command Mode
Global Config