116
Chapter 4—Hardware and Maintenance Repairs
Figure 30: Securing the CPU fan and heat sink assembly
5.
Connect the CPU fan cable to the CPU Fan 6 connector. See Figure 19 on
page 109.
6.
If you have other options to install or remove, do so now.
7.
Return the FusionIN board. See
Installing the FusionIN Board
on page 100.
8.
Return the rear fan. See
Installing the Rear Fan
on page 124.
9.
Return the side cover. See
Returning the Side Cover
on page 94.
10. Reconnect all external cables and power cords, and turn on the server.
4.6.6 Removing and Installing the Battery
If you need to replace the battery, use a lithium battery, model number CR2032. To
avoid possible danger, read and comply with the following safety statement.
The battery is located on the system board below slot 5. See Figure 6 on page 98.
Removing the Battery
1.
Follow any special handling and installation instructions supplied with the
replacement battery.
See
System Reliability Considerations
on page 92.
2.
Turn off the IC-304 print controller and all peripheral devices. Disconnect all
external cables and power cords.
3
1
2
4
WARNING:
There is a danger of explosion if the battery is replaced incorrectly.
Replace the battery only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Note:
After you replace the battery, reconfigure the IC-304 print controller and
reset the system date and time.
Содержание IC-304 Plus
Страница 1: ...Creo Color Servers Service Manual English IC 304 Plus Print Controller Version 2 0 731 01326A EN...
Страница 2: ......
Страница 8: ...viii IC 304 Print Controller 2 0 for the bizhub PRO C6500 Printer Service Manual...
Страница 65: ...49 The missing disk volume is deleted as shown in the following window 4 Right click the Missing Dynamic area...
Страница 147: ......
Страница 148: ...Creo Color Servers...