Chapter 6 Adjustment
6-12
6.5
Adjust Position of Detach Detection Roller/Sensor
Adjust the positions of the detach detection roller and sensor when assembling the detach detection unit.
Work outline
Listed below are the number of people and the rough standard of work hours required for performing the
works described in this section.
Requirements
Shown below are the tools requiring to be prepared in addition to the standard tools before performing the
works in this section.
Position and adjustment parts for the detach detection roller/sensor
Adjustment block
There are 4 steps in the adjustment block:
A: Plane where roller should not touch
B: Plane where roller touch (sensor is OFF)
C: Plane where sensor goes ON
D: Plane to place on the standard plane
Standard plane is the 3 locations at the side of the hot-cathode tube lamp attachment unit. Adjust at the
top and bottom locations, and confirm at the center area with the roller rotating.
Personnel
Number
Work Hours (steps 2 to 12)
1
No.
Tool
No.
Tool
1
Detach the detection unit adjusting jig
(Adjustment block, sensor status detection
jig)
2
Maintenance PC
Or power outlet to USB adapter
It will be used as power supply for the sensor
status detection jig.
Top Roller Support Plate
Detach Detection Roller
Bottom Roller Support
Plate
Sensor Fixing Plate
Sensor Fixing Plate
Top Detach
Detection Sensor
Bottom Detach
Detection Sensor
Reference Plane
A B
C
D
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......