Chapter 5 Disassembly and Assembly
5-97
5.9.4 Replacing the Condenser
This section describes the instructions on how to replace the condenser.
Work outline
Listed below are the number of people and the rough standard of work hours required for performing the
works described in this section.
Requirements
The works in this section can be performed using only the standard tools.
1
Removal Procedures (Page 5-6)"
"5.2.3 Removing/Installing the Exterior Panel and
to remove the first front panel.
2
Remove the electric component mount panel.
•
8 hex/Phillips-head screws (M4 x 8)
Loosen all screws.
3
Remove the connectors in the figure to remove
the cables secured to the halogen power supply
unit assembly with the snap ties and the clamps.
•
Ties
•
A: Snap ties (remove them)
•
Interlock relay 2
•
4 pieces
•
Standby power supply
•
CN1 (JP23: cable)
•
CN2 (JP26: cable)
•
Halogen power supply
•
CN1 (HCN1: cable)
•
CN2 (HCN2: cable)
•
CN3 (HCN3: cable)
•
Condenser
•
JJ1A (JP1: cable)
•
JP1A (JJ1: cable)
Caution
Be sure to turn off the power supply circuit breaker and unplug the power cable from the
equipment whenever you disassemble/assemble the equipment.
Personnel
Number
Work Hours (steps 2 to 9)
1
First Front Side
JJ1
CN2/HCN2
JP1
CN1/HCN1
A
A
A
CN3/HCN3
CN1/JP23
CN2/JP26
4 Interlock
Relay 2 Lines
First Front Side
Caution
When removing the connector, hold a notch
on the connector without pulling a cable.
Giving a strong pull to the cable may cause
it to be broken.
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......