Chapter 3 Troubleshooting
3-24
3.2.12 06550 : Optical Unit/Eraser Unit Errors
•
Error codes S column: Errors at the read operation/calibration.
•
Error codes E column: Errors during erase operation.
•
Error codes I column: Errors during initialization.
References for response method
•
See
"5.2.5 Removing/Installing the Optical Unit (Page 5-11)"
for the procedure to replace the optical
unit.
3.2.13 06600: Fan Error
References for response method
•
See
for the position of the digital power supply cooling fan.
•
See
for the position of the MDU.
•
See
"5.9.13 Replacing the Digital Power Supply Cooling Fan (Page 5-112)"
for the procedure to
replace the digital power supply cooling fan.
•
See
"5.10.2 Replacing the MDU (Page 5-116)"
for the procedure to replace the MDU.
Error code
Description of the error
Response
(References to replacement methods are
listed at the end of the table.)
S
E
I
06550
-
-
Polygon rotation error
Rotation of the polygon was not
stable when the push plate unit
moved to the read position.
Replace the optical unit.
Error
code
Description of the error
Response
(References to replacement methods are listed at the end
of the table.)
06600
Digital power supply cooling
fan blowout
Fan blowout was detected when
the digital power supply cooling
fan tried to turn.
Confirm following and replace the faulty parts.
•
Digital power supply cooling fan
•
Fan wire: JJ49 ~ JP11/JJ11 ~ MCN9 (MDU)
•
MDU
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......