Chapter 2 Before the Repair
2-28
Initialization and operation check sequence of the mechanical unit
Check Cassette Detection
Sensor
Shutter Open
End
Shutter Close
Shutter Open
Shutter Close
Inverter ON
Initialize
Subscan Unit
Move Justifier Minutely toward
Cassette Fixing Direction
Move Justifier
to Justifier HP
Move Subscan
Unit to
Mechanical HP
Move Receiver
to Second Falling
Position for 14 x 17
Move Justifier to
Cassette Fixing Position
for 15 cm x 30 cm
Move Subscan
Unit to Subscan
Mechanical Position
Transporter
at Read Position?
Move Subscan
Unit to
Mechanical HP
Shutter Close?
Jam Evacuation
Action
Wait for Door
Open
Wait for Door
Close
Move Down
Receiver Minutely
Move Receiver
to HP
Move Receiver
to HP
Receiver at
HP Position?
Justifier at
HP Position?
Move Justifier
to HP
Move Transporter
to HP
Move Transporter to
Press Down Position
Move Transporter
to Read Position
Move Transporter
to HP Pass Position
Move Transporter
to HP
Turn ON
Erase Lamp
Confirm
Illumination
Turn OFF
Erase Lamp
Lock Action
Start
With Cassette
Cassette Check in the
Equipment is Completed
Initialization of
Receiver is Completed
Justifier Warm-up
Action is Completed
Receiver Warm-up is Completed
Transporter
Warm-up is Completed
Lock Warm-up is Completed
Erase Lamp Illumination
Confirmation is Completed
Shutter Warm-up
Action is Completed
Initialization of
Subscan Unit is Completed
Subscan Unit
Warm-up Action is Completed
Initialization of
Justifier is Completed
Evacuation of
Transporter is Completed
No
Without Cassette
Yes
No
Yes
No
Yes
No
Yes
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......