Chapter 2 Before the Repair
2-30
2.6.4 Erase Action
Erase mode is composed of 2 modes.
It will go into the erase mode (quick) by pressing the erase switch for more than 3 seconds when the
equipment is in READY status. It will transit to the erase mode (slow) by pressing the erase switch in the
erase mode (quick) status.
This erase action will perform the same action as normal image read/erase action, but only the read
action will not be performed.
2.6.5 Optical Unit Maintenance Status
A mode user use to perform the following maintenance.
•
Replacing erase lamp unit (halogen lamp)
•
Cleaning reading unit
It will go into the optical unit maintenance mode by pressing the operation switch and the erase switch
simultaneously for more than 3 seconds when the equipment is in READY status.
Optical unit maintenance flow
Clean up ScanUnit?
㨅㧦㨛㨜㨑㨞㨍㨠㨕㨛㨚
㧺㧦㨑㨞㨍㨟㨑
Change Halogen Lamp?
㨅㧦㨛㨜㨑㨞㨍㨠㨕㨛㨚
㧺㧦㨑㨞㨍㨟㨑
Door Open
Perform Optical
Unit Cleaning
Door Close
Door Open
Perform Lamp
Replacement
Door Close
Press "operation"
Switch
Press "erase"
Switch
Press "operation"
Switch
Press "erase"
Switch
To clean the optical unit
To replace the lamp
To replace the lamp
To cancel
Did you change lamp?
㨅㧦㨛㨜㨑㨞㨍㨠㨕㨛㨚
㧺㧦㨑㨞㨍㨟㨑
Press "operation"
Switch
Press "erase"
Switch
When the lamp was replaced When the lamp was not replaced
ScanUnit MAINTENANCE
PREPARATION FINISH
ScanUnit MAINTENANCE
PREPARING
㧵㧺㧵㨀㧵㧭㧸㧵㨆㧵㧺㧳
عععععغغغغغ
㧾㧱㧭㧰㨅
(Reset the counter)
(Optical unit moves to second front side)
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......
Страница 301: ......