Chapter 3 Troubleshooting
3-6
References for response method
•
See
"2.5.2 Receiver unit (Page 2-12)"
for the position of the justifier motor and the justifier HP
sensor.
•
See
for the position of the MDU.
•
See
"5.4.1 Replacing the Justifier HP Sensor (Page 5-40)"
for the procedure to replace the justifier
HP sensor.
•
See
"5.4.3 Replacing the Justifier Motor (Page 5-42)"
for the procedure to replace the justifier motor.
•
See
"5.10.2 Replacing the MDU (Page 5-116)"
for the procedure to replace the MDU.
06008 06023 06038
Justifier HP sensor error
(when moving to HP 3)
Justifier HP sensor did not go
ON when the justifier guide was
moving from the minute opening
position to the home position.
Confirm following and replace the faulty
parts.
•
Justifier HP sensor
•
Sensor wire: JP41 ~ MCN3 (MDU)
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06009 06024 06039
Justifier motor control error
(when moving to HP 3)
There was a trouble with the
motor control when the justifier
guide was moving from the
minute opening position to the
home position.
Confirm following and replace the faulty
parts.
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06010 06025 06040
Justifier HP sensor error
(when moving to minute
opening position)
Justifier HP sensor did not go
OFF when the justifier guide
was moving from the home
position to the minute opening
position.
Confirm following and replace the faulty
parts.
•
Justifier HP sensor
•
Sensor wire: JP41 ~ MCN3 (MDU)
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06011 06026 06041
Justifier motor control error
(when moving to minute
opening position 2)
There was a trouble with the
motor control when the justifier
guide was moving from the
home position to the minute
opening position.
Confirm following and replace the faulty
parts.
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
Error code
Description of the error
Response
(References to replacement methods are
listed at the end of the table.)
S
E
I
Содержание 0902
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 30: ...2 10...
Страница 54: ......
Страница 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Страница 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Страница 120: ......
Страница 296: ...8 10...
Страница 300: ......