TEST THE LEVEL OF REFRIGERANT FOR AIR CONDITIONER (GAS)
k
k
WARNING
• Never touch the refrigerant.
Do not loosen any part of the refrigerant circuit.
If the refrigerant used in the air conditioner gets into your eyes or is splashed on your hands, it may
cause loss of sight or frostbite.
• Do not bring any open flame close to any point where the refrigerant (gas) is leaking.
If the level of the refrigerant (gas) is low, the cooling effect will be reduced. Perform the check while running the
engine at high idle and operating the air conditioner at high speed.
Check the condition of the refrigerant gas (Hydrofluorocarbons
HFC-134a) that circulates the refrigerant circuit, through the
sight glass (1) (inspection window) of the receiver.
(A) Proper
No bubbles in refrigerant flow
(B) Insufficient
Some bubbles in refrigerant flow (bubbles pass continuously)
(C) None
Transparent with no color
REMARK
When there are bubbles, the refrigerant (gas) level is low, so ask your Komatsu distributor to add refrigerant. If
the air conditioner continues to run with low refrigerant (gas) level, it will cause damage to the compressor.
MAINTENANCE
MAINTENANCE PROCEDURE
4-53
Содержание PC45MR-30403
Страница 61: ......
Страница 62: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 64: ...14 Engine rear cover 15 Cooling cover 16 Battery 17 KDPF OPERATION GENERAL VIEW 3 3...
Страница 310: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 411: ......
Страница 412: ...SPECIFICATIONS 5 1...
Страница 417: ......
Страница 459: ......
Страница 460: ...REPLACEMENT PARTS 7 1...
Страница 475: ...PC45MR 5 PC55MR 5 HYDRAULIC EXCAVATOR Form No TEN00763 04 2018 KOMATSU All Rights Reserved Printed in Japan 02 2018...